Rockwell Automation Publication D2-3518-3 - May 2013

175

Chapter 9

The base frequency for the motor, for the purpose of calculating the optimal DC
bus voltage.

This parameter is only used when Vdc Optimize (102) is set to Enabled.

See the description of Max Motor Volts (107) for a full description of how this
parameter is used.

Base Motor Freq (109) normally has the same value as inverter parameter Motor
NP Hertz (43).

Voltage Major Loop integral gain.

Voltage Major Loop proportional gain.

Current Minor Loop integral gain.

109

Base Motor Freq

Range:

5.0...400.0 [0.1 Hz]

Default:

60.0

Access:

0

Path: Dynamic Control > Load Limits

See also:

102, 104, 107, 108, inverter 43

110

VML Ki

Range:

0...65535

Default:

Based on drive size

Access:

0

Path: Dynamic Control > Regulator Tuning

See also:

111

VML Kp

Range:

0...65535

Default:

Based on drive size

Access:

0

Path: Dynamic Control > Regulator Tuning

See also:

112

CML Ki

Range:

0...65535

Default:

Based on drive size

Access:

0

Path: Dynamic Control > Regulator Tuning

See also: