Rockwell Automation Liqui-Flo V2.0 AC Drive User Manual
Page 121

Rockwell Automation Publication D2-3518-3 - May 2013
121
Chapter 9
Indicates Type 1 alarm conditions that currently exist in the drive. Note that for
alarm conditions not configured in Alarm Config 1 (259), the status indicated is
a zero.
for more information about alarms.
Figure 47 - Drive Alarm 1 (211)
Indicates Type 2 alarm conditions that currently exist in the drive. See
for more information about alarms.
Figure 48 - Drive Alarm 2 (212)
211
Drive Alarm 1
Range:
See
Default:
Read Only
Access:
1
Path: Utility > Diagnostics
Utility > Alarms
See also:
212, 259
212
Drive Alarm 2
Range:
See
Default:
Read Only
Access:
1
Path: Utility > Diagnostics
Utility > Alarms
See also:
211
0
0
0
0
0
0
x
0
0
0
0
0
0
x
x
x
0
0
1
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Alarm Active
0 =Alarm Inactive
x =Reserved
Bit #
Prechrg Actv
UnderV
oltage
Po
w
er Loss
Str At PwrUp
Anlg in Loss
IntDBRes OH
Dr
v OL Lvl 1
Dr
v OL L
Vl 2
Decel Inhibit
Waking
Not Synced
Phased ACB
Nibble 1
Nibble 2
Nibble 3
Nibble 4
0
0
0
0
0
0
0
0
0
0
0
0
0
x
x
x
0
0
1
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Alarm Active
0 =Alarm Inactive
x =Reserved
Bit #
DigIn CflctA
DigIn CflctB
DigIn CflctC
Bipolr Cflct
MtrT
yp Cflct
NP Hz Cflc
t
MaxF
rq Cflct
VHz NegSlope
IR Vlts
Rang
FlxAmps Rang
SpdRef Cflct
Ixo V
olt
Range
Sleep Config
Nibble 1
Nibble 2
Nibble 3
Nibble 4