102

Powermax125 Service Manual 808070

7 – Mechanized Cutting

Machine interface pinout

Figure 2 – Connector sockets

Refer to

Table 11 when connecting the power supply to a torch height controller or CNC controller with a machine

interface cable.

Table 11 – Machine interface cable signals

Signal

Type

Notes

Connector sockets

External cable wires

Start (start
plasma)

Input

Normally open.

18 VDC open circuit voltage at
START terminals. Requires dry
contact closure to activate.

3, 4

Green, black

Transfer (start
machine motion)

Output

Normally open. Dry contact closure
when the arc transfers.

120 VAC/1 A maximum at the
machine interface relay.

12, 14

Red, black

Ground

Ground

13

Voltage divider

Output

Divided arc signal of 20:1, 21.1:1,
30:1, 40:1, 50:1 (provides a
maximum of 16 V).

5 (-), 6 (+)

Black (-), white (+)