9 – power supply component replacement, Figure 44 – Hypertherm Powermax125 Service Manua User Manual

Page 176

Advertising
background image

176

Powermax125 Service Manual 808070

9 – Power Supply Component Replacement

Replacing the machine interface cable with voltage divider board

Remove the machine interface cable with voltage divider board

Figure 43

1. Complete the following procedures:

a. See Disconnect the power and gas supply on page 166.

b. See Remove the power supply cover on page 172.

c. See Remove the component barrier on page 173.

2. Disconnect the cable connectors at J18 and J32.

Figure 44

Kit number

Description

228884

Kit: Powermax105/125 machine interface cable, internal cable with voltage divider board
(CPC port)

J18

J32

Ground

J22

J27

WORK

LEAD

J26

_

RED

J18

ORG

J17

J32

J11

B

R

J28

RED

J32

J18

Power board

Advertising
This manual is related to the following products: