Minimum inlet pressure (while gas is flowing), Gas flow rates – Hypertherm Powermax125 Service Manua User Manual

Page 38

Advertising
background image

38

Powermax125 Service Manual 808070

2 – Power Supply Setup

Minimum inlet pressure (while gas is flowing)

This table shows the minimum required inlet pressure when the recommended inlet pressure is not available.

Gas flow rates

Torch lead length

7.6 m (25 feet)

15.2 m (50 feet)

22.9 m (75 feet)

Process

Minimum inlet pressure

Cutting

5.9 bar (85 psi)

5.9 bar (85 psi)

6.6 bar (95 psi)

Gouging

4.1 bar (60 psi)

4.1 bar (60 psi)

4.1 bar (60 psi)

Process

Gas flow rate

Cutting

260 slpm (550 scfh, 9.2 scfm) at a minimum:

• 5.9 bar (85 psi) for 7.6 m (25 foot) and 15 m (50 foot) torches

• 6.6 bar (95 psi) for 23 m (75 foot) torches

Gouging

212 slpm (450 scfh, 7.5 scfm) at a minimum 4.1 bar (60 psi)

Advertising