Hypertherm Powermax125 Service Manua User Manual

Page 277

Advertising
background image

Powermax125 Service Manual 808070

277

10 – Torch Component Replacement

4. Apply threadlocker (330103) to the threads of the gas tube fitting on the torch body. Be careful not to get any

threadlocker on the conical surface of the gas tube fitting to avoid damage to the torch.

Figure 133

5. Thread the torch body into the torch lead until snug.

The white wires of the lead should be facing up.

6. Use a 3/8-inch and 1/2-inch wrench together (or 2 adjustable wrenches) to tighten the gas fitting that secures the

torch body to the torch lead to 69.1 kg-cm (60 inch-pounds).

7. Tighten the pilot terminal screw to 17.3 kg-cm (15 inch-pounds).

The wire should go down into the left handle. Bend the terminal slightly if necessary.

8. Complete the following procedures:

a. Install all of the torch components that you removed. See Install the handle on page 272.

b. Reconnect the torch and gas supply, and turn ON (I) the power.

CAUTION!

Do not get any threadlocker on the conical surface of the gas tube fitting to avoid causing damage
to the torch. If any threadlocker does get on this surface, clean it off immediately.

Conical surface of the gas tube
fitting

Advertising