Fault code format – 1-nn-n, Fault code format – 2-nn-n – Hypertherm Powermax125 Service Manua User Manual

Page 138

Advertising
background image

138

Powermax125 Service Manual 808070

8 – Troubleshooting and System Tests

Fault code format – 1-nn-n

These fault codes can only be seen on the service screen.

Fault code format – 2-nn-n

These fault codes usually relate to either the DSP or the power board and can only be seen on the service screen.

1-nn-n

Fault
code

Description

Power
LED

Fault
LED

Fault
icon

Solutions

1-00-0

Digital signal processor fault

On

On

These are internal processor checks and
are not likely to be caused by a hardware
failure.

• Perform a cold restart.

If that does not fix the problem, it is
possible that the DSP or power board has
failed.

1-10-0

Analog to Digital (A/D)
converter fault

1-20-0

I/O fault

2-nn-n

Fault
code

Description

Power
LED

Fault
LED

Fault
icon

Solutions

2-00-0

Analog to Digital (A/D)
converter value out of range

On

On

• Perform a cold restart.

If that does not fix the problem, it is
possible that the DSP or power board has
failed.

2-01-0

Auxiliary switch disconnected

• Check the auxiliary switch cable.

• Perform

Test 12 – AUX switch on

page 164.

2-10-0

Inverter module temperature
sensor open

• Check the associated wiring.

• Perform

Test 4 – Inverter temperature

sensor on page 154.

If no problems are found, it is possible
that the inverter heatsink temperature
sensor assembly (228805) has failed.

2-10-1

Inverter module temperature
sensor shorted

Advertising
This manual is related to the following products: