65 a shielded cutting – mild steel – Hypertherm Powermax125 Service Manua User Manual

Page 89

Advertising
background image

Powermax125 Service Manual 808070

89

6 – Machine Torch Setup

65 A shielded cutting – mild steel

Air flow rate – slpm/scfh

Hot

222 / 470

Cold

250 / 530

Metric

Material

Thickness

Torch-to-Work

Distance

Initial Pierce Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

volts

mm/min

volts

2

1.5

3.8

250

0.1

5930

122

7015

123

3

0.2

5150

123

6080

123

4

0.5

4370

123

5145

123

6

2815

125

3275

124

8

2080

127

2235

126

10

4.5

300

0.7

1520

129

1490

128

12

1.2

960

131

1140

130

16

6

400

2.0

656

136

740

135

20

Edge start

355

141

450

140

25

215

146

270

146

English

Material

Thickness

Torch-to-Work

Distance

Initial Pierce Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

inches

inches

inches

%

seconds

ipm

volts

ipm

volts

16 GA

0.06

0.15

250

0.1

248

122

294

122

10 GA

190

123

224

123

3/16

0.2

149

124

174

123

1/4

0.5

100

125

116

124

3/8

0.7

65

129

62

128

1/2

0.18

300

1.2

30

132

40

131

5/8

0.24

400

2.0

23

136

30

135

3/4

Edge Start

15

140

19

139

7/8

12

143

15

143

1

8

146

10

146

Advertising
This manual is related to the following products: