125 a shielded cutting – stainless steel – Hypertherm Powermax125 Service Manua User Manual

Page 82

Advertising
background image

82

Powermax125 Service Manual 808070

6 – Machine Torch Setup

125 A shielded cutting – stainless steel

Air flow rate – slpm/scfh

Hot

260 / 550

Cold

345 / 730

Metric

Material

Thickness

Torch-to-Work

Distance

Initial Pierce Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

volts

mm/min

volts

6

4.6

9.2

200

0.5

5910

156

7690

157

8

4060

157

5550

157

10

2540

159

3700

157

12

2170

163

2710

157

16

11.5

250

0.7

1140

165

1460

162

20

1.2

940

167

1030

163

25

Edge Start

1.0

540

172

760

166

30

510

173

610

166

32

1.1

400

177

600

169

35

1.2

320

180

450

173

40

180

185

210

179

English

Material

Thickness

Torch-to-Work

Distance

Initial Pierce Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

inches

inches

inches

%

seconds

ipm

volts

ipm

volts

1/4

0.18

0.36

200

0.5

220

156

288

157

3/8

104

158

154

157

1/2

78

163

98

158

5/8

0.45

250

0.7

45

165

58

162

3/4

1.2

40

167

43

163

7/8

Edge Start

0.8

30

168

35

164

1

1.0

20

173

29

166

1-1/4

1.1

16

177

24

169

1-1/2

1.2

9

183

12

177

Advertising
This manual is related to the following products: