Set the operating mode switch, Check the indicators – Hypertherm Powermax125 Service Manua User Manual

Page 47

Advertising
background image

Powermax125 Service Manual 808070

47

3 – Basic System Operations

Set the operating mode switch

Use the operating mode switch to select the type of work you want to perform.

In automatic gas mode, Smart Sense technology automatically adjusts the gas pressure according to the selected cutting
mode and torch lead length for optimum cutting.

Check the indicators

Verify the following:

The green power ON LED on the front of the power supply is illuminated.

The Fault LED is

not illuminated.

No error icons appear in the status screen.

If a fault icon appears in the status screen, or the Fault LED is illuminated, or the power ON LED is blinking, correct the
fault condition before continuing. More troubleshooting information is included later in this manual.

For cutting expanded metal, grates, metal containing holes, or any job that
requires a continuous pilot arc. Using this mode to cut standard metal plate
reduces consumable life.

For cutting or piercing metal. This is the standard setting for normal drag-cutting.

For gouging metal.

Using this mode while cutting results in poor cut
quality.

For locking the torch in the ON (fire) position. With this option selected, press the
trigger to fire the torch. The trigger will remain on when you release the trigger.
The arc will go out when transfer is lost or you press the trigger again.

Advertising
This manual is related to the following products: