9 – power supply component replacement, Figure 92 – Hypertherm Powermax125 Service Manua User Manual

Page 235

Advertising
background image

Powermax125 Service Manual 808070

235

9 – Power Supply Component Replacement

8. Secure the nozzle wires ring terminal to the power board by tightening the screw to 23 kg-cm (20 inch-pounds).

9. Plug the torch interface cable connector into the J17 socket on the power board. Align the orange wire in the

connector with the “ORG” that is printed on the power board.

Figure 92

10. Complete the following procedures:

a. See Install the fan shroud on page 216.

b. See Install the end panel bracket on page 175.

c. See Install the component barrier on page 173.

d. See Install the power supply cover on page 172.

e. Reconnect the power and gas supply.

J22

J27

WORK

LEAD

J26

_

RED

J18

ORG

J17

J32

J11

B

R

J28

RED

J17

Nozzle wire screw

Power board