Powermax125 Service Manual 808070

151

8 – Troubleshooting and System Tests

If there is a fault and the diode bridge output value is correct:

Display the service screen (

Figure 21) and confirm that the value “VL” is ±15% of AC line voltage.

Figure 21

If there is a fault and the “VL” value is correct:

Verify the DSP board by replacing it with a known good board.

If the DSP board is not the problem, replace the power board.