Replacing the cap sensor switch – Hypertherm Powermax125 Service Manua User Manual

Page 287

Advertising
background image

Powermax125 Service Manual 808070

287

10 – Torch Component Replacement

Replacing the cap sensor switch

Remove the cap sensor switch

1. Complete the following procedures:

a. See Disconnect the power, gas supply, and torch on page 266.

b. See Remove the mounting sleeve on page 285.

2. Disconnect the cap-sensor switch by pressing the tab on the connector and pulling the connector apart.

Figure 144

3. Remove the screw from the cap-sensor switch and remove the switch from the torch body.

Figure 145

Install the cap-sensor switch

1. Install the cap-sensor switch and screw.

2. Connect the cap-sensor switch to the torch lead.

3. Complete the following procedures:

a. See Install the mounting sleeve on page 286.

b. Reconnect the torch and gas supply, and turn ON (I) the power.

Kit

Description

228720

Kit: Duramax/Hyamp/MRT 180° machine torch cap-sensor switch replacement

Advertising