Powermax125 Service Manual 808070

9 – Power Supply Component Replacement

9. Attach the green/yellow ground wire ring connector to the threaded post located between the center and left

grommets. (See

Figure 56.) Tighten the supplied nut onto the threaded post to 17.3 kg-cm (15 inch-pounds).

10. Push the ground wire connector through the center grommet.

Figure 56

11. From the power board side of the power supply, secure the RS-485 board to the plastic mounting posts located on

the center panel directly behind the DSP board. Tighten the 2 supplied screws to 11.5 kg-cm (10 inch-pounds). See
Figure 58 on page 187.

12. Attach the ground wire connector to the bottom left connector on the RS-485 board.

Figure 57

Left grommet

Ground wire

Center grommet

RS-485 board

Ground wire

connector