Replacing the work lead connector – Hypertherm Powermax125 Service Manua User Manual

Page 169

Advertising
background image

Powermax125 Service Manual 808070

169

9 – Power Supply Component Replacement

Replacing the work lead connector

1. Disconnect the power and gas supply. (See Disconnect the power and gas supply on page 166.)

2. Use cable cutters to cut the orange work lead cable close to the rubber boot so that both the rubber boot and the

work lead connector are removed from the cable.

Figure 33

3. Slide the new rubber boot over the work lead cable.

4. Strip 13 mm (0.5 inches) off the end of the work lead cable.

5. Insert the stripped end of the work lead cable into the new work lead connector. Tighten the set screw to

115.2 kg-cm (100 inch-pounds).

Figure 34

6. Align the tabs in the rubber boot with the mating slots in the work lead connector. Slide the rubber boot over the work

lead connector until it is fully seated.

Figure 35

Kit number

Description

228891

Kit: Powermax105/125 work lead connector replacement (lead side)

Work lead connector

Rubber boot

Work lead cable (orange)

Set screw

Stripped end of work lead cable (13 mm / 0.5 inches)

Tab

Slot