8 – Troubleshooting and System Tests

For operational fault codes 0-40-2 and 0-40-3 or power board faults 2-10-0 and 2-10-1

1. Remove the inverter temperature sensor connector from the top-rear of the power board (J2).

2. Measure the resistance between pins 1 and 3 on the plug.

3. If the resistance is not within ±15% of 10 kΩ (at approximately 25°C or 77°F), replace the temperature sensor.

4. If the value is correct, remove the DSP board and measure the resistance between pins 1 and 3 on the power board

with the temperature sensor disconnected. The resistance should be approximately 57.6 kΩ.

5. If the value is correct, replace the DSP board.

6. If the value is incorrect, replace the power board.

Figure 24

Inverter temperature sensor

connector (J2)