Torch-related faults – continuity check, Torch-related – Hypertherm Powermax125 Service Manua User Manual

Page 142

Advertising
background image

142

Powermax125 Service Manual 808070

8 – Troubleshooting and System Tests

Torch-related faults – continuity check

Check for continuity between the following points:

If there is no continuity between any 2 test points, replace the torch FastConnect
receptacle.

3-51-1

Inverter saturation fault (the
inverter is over current)

On

On

Upper and lower inverter IGBTs are being
activated in phase rather than 180° out of
phase.

• Test the 2 inverter IGBTs in the

module.

• Perform

Test 3 – Output diodes on

page 154.

• Replace the module if either is faulty.

• If necessary, replace the power board.

3-52-0

Shoot through

3-60-0

Power board

On

On

The DSP does not recognize the power
board. The code is for future machines
where the current DSP board will not
work with future power boards.

3-70-0

Internal serial
communications fault

There is a fault with the communication
between the DSP and power board.

• Check the board connector.

• If necessary, replace either the DSP or

power board.

Torch FastConnect receptacle

J17 on the power board

5

1

7

2

6

3

8

4

9

5

10

6

11

7

12

8

3-nn-n

Fault
code

Description

Power
LED

Fault
LED

Fault
icon

Solutions