Powermax125 Service Manual 808070

2 – Power Supply Setup

Strip and prepare the power cord wires as shown in the following figure. For CE units, ferrite cores are installed around
the three power wires and around the ground wire; CSA and CCC models do not have ferrite cores on the power cord
wires.

CCC models do not ship with a power cord. To maintain CE certification, install power
cord kit 228886.

L1

L2

L3

L1

L2

L3

Ground

419 mm (16.5 inches)

203 mm

(8 inches)

6 mm (0.25 inch)

Route lead through strain relief

and tighten

CSA/CCC power cords

(no ferrite cores)

CE power cord

(ferrite cores on power

wires and ground wire)