Power connection for the powermax125 – Hypertherm Powermax125 Service Manua User Manual

Page 32

Advertising
background image

32

Powermax125 Service Manual 808070

2 – Power Supply Setup

Power connection for the Powermax125

Powermax125 3-phase systems are available in the following fixed-voltage configurations:

480 V CSA

600 V CSA

400 V CE

380 V CCC

To maintain CE certification, install power cord kit 228886.

The Hypertherm rated output is 30 – 125 A, 175 VDC.

Table 4 – 480 V CSA

Table 5 – 600 V CSA

Table 6 – 400 V CE

Input voltage (V)

480

Input current (A) at rated output (21.9 kW)

31

Input current (A) at arc stretch

50

Fuse, slow-blow (A)

50

Voltage tolerance

+20% / -15%

Input voltage (V)

600

Input current (A) at rated output (21.9 kW)

24

Input current (A) at arc stretch

38

Fuse, slow-blow (A)

40

Voltage tolerance

+10% / -15%

Input voltage (V)

400

Input current (A) at rated output (21.9 kW)

36

Input current (A) at arc stretch

55

Fuse, slow-blow (A)

60

Voltage tolerance

+20% / -15%

Advertising
This manual is related to the following products: