Install the power switch – Hypertherm Powermax125 Service Manua User Manual

Page 199

Advertising
background image

Powermax125 Service Manual 808070

199

9 – Power Supply Component Replacement

Install the power switch

1. Secure the power switch to the rear panel by tightening the 4 supplied mounting screws to 17.3 kg-cm

(15 inch-pounds).

2. If the RS-485 connector is installed, bend and tear the new label at the perforation.

3. Peel the backing off the label and affix to the rear panel, being careful to align the hole in the label with the

corresponding hole in the rear panel.

4. Push the power switch handle straight onto the post and tighten the handle screw to 11.5 kg-cm (10 inch-pounds).

Figure 68 – Left half of label used when RS-485 connector is installed

Figure 69 – Full label used when RS-485 connector is

not installed

1

2

3

4

4

5

6

1

Handle screw

2

Power switch handle

3

Left edge of label

4

Power switch screws (behind label)

5

Right edge of label ends at perforation

6

Optional RS-485 connector

Label perforation

Left edge of label

Right edge of label

Advertising
This manual is related to the following products: