Powermax125 Service Manual 808070

8 – Troubleshooting and System Tests

3-20-1

Dump valve

Indicates that the dump valve
is not connected.

On

On

• Check the associated wiring.

• Perform

Test 9 – Electronic regulator

on page 162.

• If necessary, replace the electronic

regulator (228687).

3-20-2

Valve ID

The DSP does not recognize the
electronic regulator.

• Check the harness from the regulator

to J6.

3-20-3

Electronic regulator is
disconnected

The electronic regulator is
not drawing current.

• Inspect the associated wiring,

particularly the 7-pin connector at J6
on the power board.

• If necessary, replace the electronic

regulator (228687).

3-41-0

Drive fault

On

On

If an activation signal is sent to a device
and the device does not activate (machine
motion relay or in-rush relay for example)
this fault will occur.

3-42-0

5 or 24 VDC fault

The 5 or 24 VDC supply from the flyback
circuit is out of range.

Perform

Test 5 – Flyback circuit (DC

minor voltages) on page 156.

3-42-1

Driver voltage fault

The 18 VDC supply from the flyback
circuit is out of range.

• Replace the power board.

• Check the inverter IGBT module and

replace if necessary.

3-nn-n

Fault
code

Description

Power
LED

Fault
LED

Fault
icon

Solutions