Hypertherm Powermax125 Service Manua User Manual

Page 116

Advertising
background image

116

Powermax125 Service Manual 808070

8 – Troubleshooting and System Tests

Figure 5 – Power switch resistance

CE models have a ferrite core installed over the ground wire and over the power wires.
CSA models do not have ferrite cores. CCC models do not ship with a power cord.

480 V, 600 V CSA models

400 V CE, 380 V CCC models

400 kΩ

400 kΩ

>20 MΩ

400 kΩ

350 kΩ

350 kΩ

350 kΩ

>20 MΩ