65 a shielded cutting – stainless steel – Hypertherm Powermax125 Service Manua User Manual

Page 90

Advertising
background image

90

Powermax125 Service Manual 808070

6 – Machine Torch Setup

65 A shielded cutting – stainless steel

Air flow rate – slpm/scfh

Hot

222 / 470

Cold

250 / 530

Metric

Material

Thickness

Torch-to-Work

Distance

Initial Pierce Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

volts

mm/min

volts

2

1.5

3.8

250

0.1

7405

119

9970

121

3

0.2

6120

120

8240

122

4

0.5

4840

122

6110

123

6

2275

125

2840

125

8

0.7

1505

127

1860

127

10

4.5

300

1115

130

1245

128

12

1.2

720

133

925

130

16

Edge Start

465

137

505

136

20

320

141

345

141

English

Material

Thickness

Torch-to-Work

Distance

Initial Pierce Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

inches

inches

inches

%

seconds

ipm

volts

ipm

volts

16 GA

0.06

0.15

250

0.1

316

118

425

120

10 GA

220

121

296

122

3/16

0.2

152

123

168

123

1/4

0.5

72

125

96

125

3/8

0.7

48

130

52

128

1/2

0.18

300

1.2

23

134

32

131

5/8

Edge Start

19

137

20

136

3/4

14

140

15

140

Advertising