Powermax125 Service Manual 808070

135

8 – Troubleshooting and System Tests

0-30-0

Torch stuck open

The nozzle and electrode are
not touching after a start is
received.

On

On

• If incorrect consumables are installed

or the consumables became loose or
were removed while the power supply
is ON, turn OFF the power supply,
correct the problem and then turn ON
the power supply to clear this fault.

• Inspect the torch for signs of wet or oily

air.

• Inspect the torch for any signs of

damage or pitting on the electrode
contact surface.

• If the consumables appear to be

installed correctly, the torch may be
damaged. Test with a known working
torch.

• Perform

Test 6 – Torch stuck

open/torch stuck closed on page 158.

• If the problem persists, contact your

Hypertherm distributor or authorized
repair facility.

0-30-1

Torch stuck closed

The nozzle and electrode will
not separate after a start is
received.

The regulator may not be
functioning properly.

0-32-0

End of consumable life (or
the power supply is working
in an electrically noisy
environment)

• Replace the electrode and nozzle.

• Check the remaining consumables for

wear and replace as needed.

• Try another circuit or move the system

to another location to eliminate
possible electrical noise.

0-nn-n

Fault
code

Description

Power
LED

Fault
LED

Fault
icon

Solutions