Powermax125 Service Manual 808070
9 – Power Supply Component Replacement
8. Remove the plastic washer.
9. Remove the silver-plated fitting by pushing it out through the front of the quick disconnect receptacle housing.
10. Remove the quick disconnect receptacle by removing the 4 mounting screws that secure the quick disconnect
receptacle to the front panel.
Figure 90
1
2
4
5
6
7
8
9
10
3
1
Torch interface cable
2
90° push-to-connect fitting
3
Brass nut
4
Electrode wire (red)
5
Protective sheathing
6
Nozzle wires (2)
7
Output inductor wires (3)
8
Plastic washer
9
Quick disconnect receptacle
10 Center grommet