Replacing the work lead receptacle – Hypertherm Powermax125 Service Manua User Manual

Page 236

Advertising
background image

236

Powermax125 Service Manual 808070

9 – Power Supply Component Replacement

Replacing the work lead receptacle

1. Complete the following procedures:

a. See Disconnect the power and gas supply on page 166.

b. See Remove the power supply cover on page 172.

c. See Remove the fan shroud on page 216.

2. Remove the bolt securing the work cable to the work lead receptacle.

3. Remove the nut and lock washer securing the work lead receptacle to the front panel.

4. Push the work lead receptacle out through the front panel.

Figure 93

Kit number

Description

228912

Kit: Powermax105/125 work lead receptacle (power supply side)

1

2

3

4

5

1

Work lead receptacle

2

Bolt

3

Work cable

4

Nut

5

Lock washer

Advertising
This manual is related to the following products: