8 – Troubleshooting and System Tests

Perform a cold restart

Sometimes a “cold restart” clears the fault. When a cold restart is recommended in one of the

Solutions below, do the

following:

1. Power OFF the machine.

2. Wait 30 seconds or until the red LED near the top of the DSP board blinks once.

3. Power ON the machine.

Fault codes and solutions

Each table below describes a fault category and suggests solutions for each fault code. Several of the fault solutions
show a test number. Refer to

System tests on page 149 to perform the indicated numbered test.

If a fault occurs while using a generator, turning the power switch quickly to OFF and then
to ON again (sometimes called a “quick reset”) may not clear the fault. Instead, see
Perform a cold restart on page 131.

Fault code format – 0-00-0

This fault code indicates normal operations.

0-00-0

Fault
code

Description

Power
LED

Fault
LED

Fault
icon

Solutions

0-00-0

None

On

Off

-

No errors