Powermax125 Service Manual 808070

291

10 – Torch Component Replacement

Replacing the quick disconnect housing

1. Turn OFF (O) the power, disconnect the gas supply, and disconnect the torch.

2. Remove the screws from the bottom half of the shell. (See Figure 148 on page 291.)

3. Remove the 2 shell halves.

4. Remove the latch by using a blade screwdriver to press down firmly on the latch tab while pushing the tab down and

out toward the lead.

5. Pull the spring out of the quick disconnect housing.

Figure 148

6. Place the new latch into the quick disconnect housing.

7. Hold up the end of the latch and insert the new spring under the latch.

8. Use a blade screwdriver to push the spring into the recess until it clicks into place.

Kit

Description

428260

Kit: Duramax and Duramax Hyamp torch quick disconnect repair (lead side)

1

2

3

4

5

6

7

8

9

10

1

Top shell half

2

Latch tab

3

Quick disconnect housing

4

Bottom shell half

5

Screws (4)

6

Strain relief slot

7

Torch lead

8

Strain relief

9

Spring

10 Latch

Advertising