Powermax125 Service Manual 808070

129

8 – Troubleshooting and System Tests

Figure 17

Fault codes beginning with zero (0-

nn-n) are not recorded in the fault log.

To move the field selector (*) between fields, press the current/gas mode selector. The asterisk indicates the selected
field. You can alter the I, C, B, P, and G fields by turning the adjustment knob.

To toggle between (I) Current set/read and (P) Pressure set/read, press the automatic/manual mode selector. The LED is
illuminated when the Pressure set/read field is selected.

To exit the service screen, simultaneously press the automatic/manual and current/gas mode selectors. The operator
screen displays.

Designator

Description

I

Current set/read

C

LCD contrast

B

LCD brightness (percent)

P

Pressure set/read

G

Gas test enable (1)/disable (0)

VL

Incoming AC line voltage

TI

Inverter module temperature (°C)

VB

DC bus voltage

AH

Arc hours

F

Live 4-digit fault code for diagnosing system errors

T

Torch identifier (amperage/hand (H) or machine (M)/lead length in feet)

S

Control/DSP board software versions

(callouts 1 – 6)

Fault log of recent fault codes recorded by the system (0-00-0) and the
last 3 digits of the arc hour count when the fault occurred (000). Callout 1
is the most recent fault code.

1
3
5

2
4
6