Hypertherm Powermax125 Service Manua User Manual

Page 144

Advertising
background image

144

Powermax125 Service Manual 808070

8 – Troubleshooting and System Tests

Power ON LED
blinks or goes out
while cutting.

A power component is
shorted.

• Faulty fan.

• Perform

Test 11 – Fan on page 164.

• Faulty power board

or IGBT.

• Perform

Test 1 – Voltage input on

page 150,

Test 2 – DC power bus on

page 152, or

Test 3 – Output diodes

on page 154.

• Faulty DSP board.

The arc does not
transfer to the
workpiece.

Poor continuity exists
between the work lead and
the workpiece.

• The workpiece is

dirty.

• The ground clamp is

damaged.

• The pierce height

distance is too large.

• Clean the area where the ground

clamp contacts the workpiece to
allow a good metal-to-metal
connection.

• Inspect the ground clamp for damage,

and repair as necessary.

• The pierce height distance may be too

large. Move the torch closer to the
workpiece and fire the torch again.

Gas flows from
the torch at
power-up when
neither the torch
trigger nor a
remote start is
activated.

The electronic regulator,
power board, or control
board is faulty.

• Faulty electronic

regulator.

• Faulty power board.

• Faulty DSP board.

• Perform

Test 9 – Electronic regulator

on page 162.

The incoming gas pressure is
too high.

• The gas pressure

from the compressor
or cylinder may be
too high.

• Check the gas supply to make sure

that it does not exceed 9.3 bar
(135 psi). If necessary, reduce the
pressure.

Problem

Meaning

Causes

Solution

Advertising
This manual is related to the following products: