Replacing the trigger assembly – Hypertherm Powermax125 Service Manua User Manual

Page 274

Advertising
background image

274

Powermax125 Service Manual 808070

10 – Torch Component Replacement

11. Make sure the trigger is in its pivot holes by pulling it a few times.

12. Tighten the handle screws to15.0 kg-cm (13 inch-pounds).

13. Install the consumables.

14. Reconnect the torch and gas supply, and turn ON (I) the power.

Replacing the trigger assembly

1. Turn OFF (O) the power, disconnect the gas supply, and disconnect the torch.

2. Remove the consumables from the torch.

3. Place the torch on a flat surface with the left handle facing up.

4. Remove the screws from the left handle. Set the screws aside.

5. Being careful to keep the trigger spring from launching out of the handle, lift the left side of the handle away from the

torch.

Figure 129

For the 15° hand torch, carefully lift up the right end of the handle. Insert a blade
screwdriver between the handles on the left end. Gently twist the screwdriver to pry up
the handle. (See

Figure 130.)

Kit

Description

428156

Kit: Duramax Hyamp hand torch trigger with spring replacement

CAUTION!

Wear eye protection, as the trigger spring can launch out of the handle.