Hypertherm power supply ratings, 1 – specifications – Hypertherm Powermax125 Service Manua User Manual

Page 22

Advertising
background image

22

Powermax125 Service Manual 808070

1 – Specifications

Hypertherm power supply ratings

Rated open-circuit voltage (U

0

)

480/600 V CSA

400 V CE

380 V CCC

320 VDC

305 VDC

290 VDC

Output characteristic

1

Drooping

Rated output current (I

2

)

30 – 125 A

Rated output voltage (U

2

)

175 VDC

Duty cycle at 40° C (104° F)

480/600 V CSA

400 V CE

380 V CCC

100% at 125 A, 480/600 V, 3-PH

100% at 125 A, 400 V, 3-PH

100% at 125 A, 380 V, 3-PH

Operating temperature

-10° to 40° C (14° to 104° F)

Storage temperature

-25° to 55° C (-13° to 131° F)

Power factor

0.94

R

sce

– Short Circuit Ratio (CE models

only)

U

1

– Volts AC rms, 3-PH

R

sce

400 V CE

250

EMC emissions classification
CISPR 11 (CE models only)

2

Class A

Input voltage (U

1

)/ Input current (I

1

) at

rated output (U

2 MAX

I

2 MAX

)

(See

Power Supply Setup on

page 29.)

480/600 V CSA 480/600 V, 3-PH, 50/60 Hz, 31/24 A

400 V CE

3,4

400 V, 3-PH, 50/60 Hz, 36 A

380 V CC 380 V, 3-PH, 50/60 Hz, 38 A

Gas type

Air

Nitrogen

Gas quality

Clean, dry, oil-free per ISO 8573-1

Class 1.2.2

99.95% pure

Recommended gas inlet flow
rate/pressure

Cutting: 260 slpm (550 scfh, 9.2 scfm) at:

• 5.9 bar (85 psi) for 7.6 m (25 foot) and 15 m (50 foot) torches

• 6.6 bar (95 psi) for 23 m (75 foot) torches

Gouging: 212 slpm (450 scfh, 7.5 scfm) at 4.1 bar (60 psi)

1

Defined as a plot of output voltage versus output current.

2

This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public
low-voltage supply system. There may be potential difficulties in ensuring electromagnetic compatibility in those locations due to
conducted or radiated disturbances.

3

This product meets the technical requirements of IEC 61000-3-3 and is not subject to conditional connection.

4

Equipment complies with IEC 61000-3-12 provided that the short-circuit power S

sc

is greater than or equal to 5363 KVA at the

interface point between the user’s supply and the public system. It is the responsibility of the installer or user of the equipment to
ensure, by consultation with the distribution network operator if necessary, that the equipment is connected only to a supply with
a short-circuit power S

sc

greater than or equal to 5363 KVA.