Powermax125 Service Manual 808070

8 – Troubleshooting and System Tests

Fault code format – 0-nn-n

These fault codes identify operational faults. On the operator screen, the last digit is omitted. Display the service screen
for more information on faults 11, 19, 30, 40, 60, and 99.

Fault codes beginning with zero (0-

nn-n) are not recorded in the fault log.

0-nn-n

Fault
code

Description

Power
LED

Fault
LED

Fault
icon

Solutions

0-11-0

Remote controller cut mode
invalid. Valid remote cut
modes for Powermax125:
1 – Normal; 2 – CPA
(continuous pilot arc);
3 – gouge; 5 – lock.

On

Off

There is a problem with the remote
controller or the software interface to the
system. The system cannot interpret the
cut mode, cut current, or pressure
information coming from the controller.

• Fix the controller.

• Check the interface cable.

0-11-1

Remote controller current
invalid. Valid remote current
settings for Powermax125
are: 30 – 125 A.

0-11-2

Remote controller pressure
invalid. Valid remote pressure
setting for Powermax125
depends on the torch.

0-12-1

Output gas pressure low

On

Off

• Adjust the gas inlet pressure as

needed.

• Check for kinked or blocked air lines.

• Perform

Test 10 – Pressure sensor on

page 163.

0-12-2

Output gas pressure high

• The gas subsystem is not working

properly. Check the valve.

• Perform

Test 10 – Pressure sensor on

page 163.

0-12-3

Output gas pressure
unstable

0-13-0

AC input unstable (line
resonance): Alert

Blinks

(3 Hz)

Off

• Perform a cold restart.

• If the fault does not clear, correct the

power source. Change the character,
generally the impedance, of the line.