Powermax125 Service Manual 808070

9 – Power Supply Component Replacement

7. Disconnect the quick disconnect receptacle from the front panel by removing the 4 mounting screws.

8. Remove the bolt securing the work cable to the work lead receptacle.

9. Remove the nut and lock washer securing the work lead receptacle to the front panel.

10. Push the work lead receptacle out through the front panel.

Figure 108

3

4

5

6

1

2

7

1

Work lead receptacle

2

Bolt

3

Work cable

4

Nut

5

Lock washer

6

Quick disconnect receptacle

7

Mounting screws (4)