Estimated kerf-width compensation, Estimated kerf-width compensation – metric (mm) – Hypertherm Powermax125 Service Manua User Manual

Page 78

Advertising
background image

78

Po

we
rma
x1

25
S

e

rv

ic

e

M
a

n

u

a

l

80
80
7

0

6

Machine Torch Setup

Estimated kerf-width compensation

The widths in the following tables are for reference. The data are obtained with the “Best Quality” settings. Differences between installations and material
composition may cause actual results to vary from those shown in the tables.

Estimated kerf-width compensation – Metric (mm)

Process

Thickness (mm)

0.5

1

2

3

6

8

10

12

16

20

25

30

32

35

40

Mild steel

125 A shielded

2.2

2.3

2.4

2.4

2.6

2.8

3.1

3.6

3.8

3.9

4.1

105 A shielded

2

2.1

2.2

2.3

2.4

2.5

2.7

3

3.2

65 A shielded

1.6

1.6

1.8

1.9

2.0

2.2

2.7

3.2

3.7

45 A shielded

1.6

1.4

1.3

1.5

1.6

FineCut

1.3

1.2

1.2

1.2

Stainless steel

125 A shielded

1.9

2.2

2.4

2.6

2.6

2.7

3.1

3

3

3.2

3.6

105 A shielded

1.6

1.9

2.2

2.3

2.4

2.5

2.9

2.9

2.9

65 A shielded

1.4

1.5

1.8

1.8

1.9

1.9

2.1

2.3

45 A shielded

1.4

1.2

1.2

1.5

1.7

FineCut

1.2

1.2

1.0

1.0

Aluminum

125 A shielded

2.3

2.5

2.6

2.6

2.8

2.9

2.8

2.9

3

3.3

3.7

105 A shielded

1.9

2.0

2.2

2.2

2.1

2.1

2.5

2.5

2.5

65 A shielded

1.9

1.9

1.9

1.9

2.0

2.0

2.1

2.2

45 A shielded

1.5

1.4

1.6

1.8

Advertising