8 – troubleshooting and system tests figure 23 – Hypertherm Powermax125 Service Manua User Manual

Page 153

Advertising
background image

Powermax125 Service Manual 808070

153

8 – Troubleshooting and System Tests

Figure 23

J22

J21

J20

J19

J27

WORK

LEAD

J26

+

_

+

_

TP7

TP9

TP8

W

R

B

325 VDC

405 VDC

270 VDC

255 VDC

650 VDC

325 VDC

810 VDC

405 VDC

540 VDC

270 VDC

510 VDC

255 VDC

480 V CSA input

Inverter IGBT

600 V CSA input

400 V CE input

380 V CCC input

Bulk capacitors

Advertising