Hypertherm Powermax125 Service Manua User Manual

Page 141

Advertising
background image

Powermax125 Service Manual 808070

141

8 – Troubleshooting and System Tests

3-43-0

Inverter capacitors
unbalanced

On

On

• Voltage across one or both inverter

capacitors is more than 25% different
than nominal.

480 V CSA units

Bus voltage is 650 VDC.

Nominal is 325 VDC for each capacitor.

Fault condition: < 235 or > 415 VDC
across either capacitor.

600 V CSA units

Bus voltage is 810 VDC.

Nominal is 405 VDC for each capacitor.

Fault condition: < 295 or > 515 VDC
across either capacitor.

400 V CE units

Bus voltage is 540 VDC.

Nominal is 270 VDC for each capacitor.

Fault condition: < 200 or > 360 VDC
across either capacitor.

380 V CCC units

Bus voltage is 510 VDC.

Nominal is 255 VDC for each capacitor.

Fault condition: < 200 or > 360 VDC
across either capacitor.

• Test the IGBT module.

• Replace the bulk capacitors.

3-nn-n

Fault
code

Description

Power
LED

Fault
LED

Fault
icon

Solutions

Advertising
This manual is related to the following products: