Hypertherm Powermax125 Service Manua User Manual

Page 146

Advertising
background image

146

Powermax125 Service Manual 808070

8 – Troubleshooting and System Tests

Arc goes out
while cutting or
intermittently will
not fire.

The arc lost contact with the
workpiece.

• The work lead or

work lead connection
may be faulty.

• The material being

cut may require the
use of continuous
pilot arc mode.

• If you are cutting expanded metal,

grate, or any metal with holes, set the
mode switch to continuous pilot arc
mode.

• Check for loose connections at the

ground clamp and at the power
supply.

• Reposition the work lead on the

workpiece.

• Clean the cutting surface to allow a

better connection with the work lead.

Faulty fan.

• The fan could be

overloading the
flyback circuit.

• Perform

Test 5 – Flyback circuit (DC

minor voltages) on page 156 and
Test 11 – Fan on page 164.

Problem

Meaning

Causes

Solution