8 – Troubleshooting and System Tests

Fault code format – 3-nn-n

These fault codes can only be seen on the service screen.

2-11-0

Pressure sensor is open

On

On

• Check the associated wiring.

• Perform

Test 10 – Pressure sensor on

page 163.

• If necessary, replace the pressure

sensor (228689).

2-11-1

Pressure sensor is shorted

2-20-0*

Torch ID

The DSP does not recognize
the torch.

• Confirm that the torch is seated

properly in the connector.

• Inspect the connector for the proper

pin-out. See

Torch-related

faults – continuity check on page 142
and

Powermax125 schematic diagram

on page 317.

* Perform a continuity check on the FastConnect receptacle on the power supply using the instructions in

Torch-related

faults – continuity check on page 142.

3-nn-n

Fault
code

Description

Power
LED

Fault
LED

Fault
icon

Solutions

3-10-0

Fan speed

The fan speed is below the
minimum speed.

On

On

• Clean the fan assembly.

• Perform

Test 11 – Fan on page 164.

3-10-1

Fan

• Check the associated wiring.

• Perform

Test 11 – Fan on page 164.

• If necessary, replace the fan assembly.

3-20-0

Fill valve

Indicates that the fill valve is
not connected.

• Check the associated wiring.

• Perform

Test 9 – Electronic regulator

on page 162.

• If necessary, replace the electronic

regulator (228687).

2-nn-n

Fault
code

Description

Power
LED

Fault
LED

Fault
icon

Solutions