9 – Power Supply Component Replacement

5. Route the long cable, small connector first, through the RS-485 mounting hole in the rear panel.

6. Fasten the RS-485 connector in the mounting hole of the rear panel, with the red wire on top (see Figure 54), by

tightening the 2 supplied screws to 11.5 kg-cm (10 inch-pounds).

Figure 54

7. Route the RS-485 cable next to the 2 existing gray cables, above the solenoid valve and through the cable clip

attached to the center panel.

8. Push the small connector from the RS-485 cable through the center grommet in the center panel.

Figure 55

Red wire

Cable clip

Solenoid valve

Center grommet