Powermax125 Service Manual 808070
185
9 – Power Supply Component Replacement
5. Route the long cable, small connector first, through the RS-485 mounting hole in the rear panel.
6. Fasten the RS-485 connector in the mounting hole of the rear panel, with the red wire on top (see Figure 54), by
tightening the 2 supplied screws to 11.5 kg-cm (10 inch-pounds).
Figure 54
7. Route the RS-485 cable next to the 2 existing gray cables, above the solenoid valve and through the cable clip
attached to the center panel.
8. Push the small connector from the RS-485 cable through the center grommet in the center panel.
Figure 55
Red wire
Cable clip
Solenoid valve
Center grommet