2 – Power Supply Setup

Extension cord recommendations

Any extension cord must have an appropriate wire size for the cord length and system voltage. Use a cord that meets
national and local codes.

For all Powermax125 configurations, the recommended gauge size for any three-phase extension cord between
3 – 45 m (10 – 150 feet) is 10 mm

2

(8 AWG).

Engine-driven generator recommendations

Generators used with the Powermax125 should satisfy the voltage requirements in the following table and in

Hypertherm

power supply ratings on page 22.

Based on the generator rating, age, and condition, adjust the cutting current as needed.

If a fault occurs while using a generator, turning the power switch quickly to OFF and then
to ON again (sometimes called a “quick reset”) may not clear the fault. Instead, turn OFF
the power supply and wait 60 to 70 seconds before turning it ON again.

Engine drive rating

System output current

Performance (arc stretch)

40 kW

125 A

Full

30 kW

125 A

Limited

30 kW

100 A

Full

25 kW

100 A

Limited

22.5 kW

75 A

Full

20 kW

75 A

Limited

20 kW

60 A

Full

15 kW

60 A

Limited

12 kW

40 A

Full

10 kW

40 A

Limited

10 kW

30 A

Full

8 kW

30 A

Limited