Action Parameter

You can set the Action parameter to Stop, Wait for Start, or Next Index.

Stop

This action stops and holds zero velocity while remaining enabled. Upon
assertion of the Start Index digital input or the Start Motion bit in the EtherNet/
IP Output Assembly, the drive begins executing the index in the Index system
parameter.

Figure 61 - Example of Stop and Hold Index Action

Wait For Start

This action waits for either the Start Motion bit to transition in the EtherNet/IP
Output Assembly or for the Start Index configured digital input to perform an
active transition.

Figure 62 - Example of Wait for Start Index Action

Next Index

This action immediately moves to the next index as defined by the Next Index
parameter.

Figure 63 - Example of Next Index Action

Position

Ve

lo

ci

ty

Position

Ve

lo

ci

ty

Index 1

Index 2

Hold zero velocity until ‘Start Index’

command

Position

Ve

lo

ci

ty

Index 1

Index 2

Dwell time at

zero velocity