Rockwell Automation Publication 2097-UM001D-EN-P - November 2012

31

Installing the Kinetix 300 Drive System

Chapter 2

Cable Categories for Kinetix 300 Drive Components

These table indicate the zoning requirements of cables connecting to the
Kinetix 300 drive components.

Table 6 - Kinetix 300 Drive Components

Noise Reduction Guidelines for Drive Accessories

See this section when mounting an AC line filter or shunt resistor module for
guidelines designed to reduce system failures caused by excessive electrical noise.

AC Line Filters

Observe these guidelines when mounting your AC line filter:

If you are using a Bulletin 2090 line filter, mount the filter on the same

panel as the Kinetix 300 drive, and as close to the drive as possible.

Good HF bonding to the panel is critical. For painted panels, see the

examples on

page 27

.

Segregate input and output wiring as far as possible.

Wire/Cable

Connector

Zone

Method

Very

Dirty

Dirty

Clean

Ferrite

Sleeve

Shielded

Cable

L1, L2, L3 (unshielded cable)

IPD

X

U, V, W (motor power)

MP

X

X

+, -, SH (shunt resistor)

BC

X

24V DC

BP

X

Control COM, 24V DC control, safety enable, and
feedback signals for safe-off feature

STO

X

Motor feedback

MF

X

X

Registration and analog outputs

IOD

X

X

Others

X

Ethernet

Port 1

X

X