Dynamics Category

The Dynamics category provides access to the configuration of the modifiable
dynamics parameters.

Click Autotuning to begin autotuning.

Table 47 - Dynamics Category

See the Servo Loop diagram on

page 98

for more information on these

parameters.

ID

Parameter Name

Description

Value/Notes

44

Velocity P-Gain

The proportional and integral gain (respectively) of the velocity loops.
Gains are based on counts as the fundamental units and they are not
physical units.

Range: 0…32767

45

Velocity I-Gain

Range: 0…32767

46

Position P-Gain

The proportional, integral, and derivative gain (respectively) of the
position loops. Gains are based on counts as the fundamental units and
they are not physical units.

Range: 0…32767

47

Position I-Gain

Range: 0…16383

48

Position D-Gain

Range: 0…32767

49

Position I-Limit

A clamping limit on the position loop I-gain compensator to prevent
excessive torque overshooting caused by an over accumulation of the I-
Gain.

Range: 0…20000

51

Gain Scaling

A 2x factor applied to the gains in the velocity loop useful for scaling the
gains when using encoders with a high number of counts per revolution.

Range: -16…+4