Three-phase power wired to single-phase drives – Rockwell Automation 2097-Vxxx Kinetix 300 EtherNet/IP Indexing Servo Drive User Manual User Manual

Page 61

Advertising
background image

Rockwell Automation Publication 2097-UM001D-EN-P - November 2012

61

Connecting the Kinetix 300 Drive System

Chapter 4

Isolation Transformer in Grounded Power Configurations

When using an isolation transformer, attach a chassis ground wire to the neutral
connection. This grounded neutral connection does the following:

Prevents the system from floating and thereby avoids any high voltages that

might otherwise occur, for example due to static electricity

Provides a solid earth path for fault conditions

Three-phase Power Wired to Single-phase Drives

This example illustrates grounded three-phase power wired to single-phase
Kinetix 300 drives when phase-to-phase voltage is within drive specifications.

Figure 36 - Single-phase Amplifiers on Three-phase Power (WYE)

(1) Contactors (MI, M2, and M3) may be optional. For more information, see Understanding the Machinery Directive, publication

SHB-

900

. AC line filter is optional, but is required for CE compliance.

Feeder short circuit protection is not illustrated.

ATTENTION: If the supply transformer is an auto transformer (not
recommended), a chassis earth ground should not be added. A chassis earth
ground should already be included elsewhere in the system and adding another
would create a short.

L1
L2

L3

IPD

L1

L2

IPD

L1

L2

IPD

L1

L2

L1

L2

L3

L2

L3

L1

2097-V32PRx

Transformer

(WYE) Secondary

Grounded Neutral

Kinetix 300 Drives

(System A)

Single-phase AC Input

Input Fusing

M1

(1)

M2

(1)

M3

(1)

Ground Grid or

Power Distribution Ground

Bonded Cabinet

Ground Bus

Kinetix 300 Drives

(System B)

Single-phase AC Input

Kinetix 300 Drives

(System C)

Single-phase AC Input

Input Fusing

Input Fusing