Ethernet connections, 24v dc back-up power, Ethernet connections 24v dc back-up power – Rockwell Automation 2097-Vxxx Kinetix 300 EtherNet/IP Indexing Servo Drive User Manual User Manual

Page 50

Advertising
background image

50

Rockwell Automation Publication 2097-UM001D-EN-P - November 2012

Chapter 3

Kinetix 300 Drive Connector Data and Feature Descriptions

Ethernet Connections

An RJ45 Ethernet connector (port 1) is provided on the Kinetix 300 drive.

Table 15 - Ethernet Communication Specifications

24V DC Back-up Power

The Kinetix 300 drive can use an external power supply to power the logic and
communication circuits. If an independent 24V (@ 1 A) power supply is
connected to the BP connector, the logic and communication circuits remain
active during a mains input power loss.

Table 16 - 24V DC Back-up Power Specifications

Attribute

Value

Communications

100BASE-TX, full duplex

Cyclic update period

2 ms, min

Auto MDI/MDIX crossover
detection/correction

Yes

Cabling

CAT5E or CAT6, unshielded or shielded, 100 m (328 ft)

Attribute

Value

Input voltage

20…26V DC

Current

500 mA

Inrush, max

30 A

Advertising