Rockwell Automation Publication 2097-UM001D-EN-P - November 2012

73

Connecting the Kinetix 300 Drive System

Chapter 4

This diagram shows an example of three-phase power wires for motors/actuators
that have no brakes. Thermal switch wires are included in the feedback cable.

See

Kinetix 300 Drive/Rotary Motor Wiring Examples

beginning on

page 176

for interconnect diagrams.

Figure 42 - Motor Power Terminations (three-phase wires only)

The cable shield clamp shown above is mounted to the subpanel. Ground and
secure the motor power cable in your system following instructions on

page 76

.

Motor Cable
Shield Clamp

Motor Power (MP) Connector Plug