Kinetix 300 drive/rotary motor wiring examples – Rockwell Automation 2097-Vxxx Kinetix 300 EtherNet/IP Indexing Servo Drive User Manual User Manual

Page 176

Advertising
background image

176

Rockwell Automation Publication 2097-UM001D-EN-P - November 2012

Appendix A

Interconnect Diagrams

Kinetix 300 Drive/Rotary
Motor Wiring Examples

These wiring diagrams apply to Kinetix 300 drives with compatible rotary
motors.

Figure 87 - MP-Series (Bulletin MPL-A/B and MPS-A/B) Motors

D/
C/W
B/V
A/U

BR-

BR+

G/-

F/+

W

V
U

0
1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

SIN+

SIN-

COS+

COS-

DATA+

DATA-

+5VDC

ECOM

GREEN

WHT/GREEN

GRAY

WHT/GRAY

BLACK

WHT/BLACK

RED

WHT/RED

3
4

5
6

1
2

9

10

1
2

3
4

5

10

14

6

14

12

+9VDC

TS+

ORANGE

WHT/ORANGE

11
13

7

11

Green/Yellow

Blue

Black

Brown

GND

BR+

BR-

F

G

W

V
U

GND

Shield

W

V
U

C
B
A

TS-

COM

BLUE

AM+

AM-

BM+

BM-

IM+

IM-

+5VDC

ECOM

BLUE

WHT/BLUE

GREEN

WHT/GREEN

GRAY

WHT/GRAY

BLACK

WHT/BLACK

RED

WHT/RED

1
2

3
4

5

10
14

6

12

TS-

S1

TS+

ORANGE

WHT/ORANGE

11

S2
S3

COM

YELLOW

WHT/YELLOW

13

8

3
4

5
6

1
2

14
15
16
17
12

11
13

9

10

Black

White

CR1

OUT4-E
OUT4-C

24V DC

24V DC COM

Motor Brake

I/O (IOD)

Connector

Note 4

Motor Power

(MP) Connector

2097-V3xPRx

Kinetix 300 Drives

MPL-A/B15xxx, MPM-A/B2xxx

and MPS-A/Bxxx

Servo Motors with

High Resolution Feedback

Motor Feedback
(MF) Connector

Three-phase
Motor Power

Motor

Feedback

Thermostat

User Supplied

24V DC

Three-phase
Motor Power

Motor

Feedback

Thermostat

MPL-A/B15xx and MPL-A/B2xx

Servo Motors with

Incremental Feedback

2090-K2CK-D15M

Connector Kit

2090-K2CK-D15M

Connector Kit

Motor Brake

See low profile connector

illustration (lower left)

for proper grounding technique.

See low profile connector

illustration (lower left)

for proper grounding technique.

Low Profile Connector
(2090-K2CK-D15M shown)

Grounding Technique for

Feedback Cable Shield

Turn clamp over to hold

small cables secure.

Exposed shield secured

under clamp.

Clamp Screws (2)

Clamp

See table on

page 172

for note information.

2090-XXNFMF-Sxx (standard) or

2090-CFBM4DF-CDAFxx (continuous-flex)

(flying-lead) Feedback Cable

Notes 9, 11

2090-XXNFMF-Sxx (non-flex) or

2090-CFBM4DF-CDAFxx (continuous-flex)

(flying-lead) Feedback Cable

Note 9

2090-XXNPMF-xxSxx (standard)

or 2090-CPBMxDF-xxAFxx

(continuous-flex)

Motor Power Cable

Notes 9, 10

Use 2090-CPWMxDF-xxAFxx

cable for continuous flex non-brake applications.

Cable Shield
Clamp

Note 8

Note 12

Note 6

Advertising