Power wiring examples – Rockwell Automation 2097-Vxxx Kinetix 300 EtherNet/IP Indexing Servo Drive User Manual User Manual

Page 173

Advertising
background image

Rockwell Automation Publication 2097-UM001D-EN-P - November 2012

173

Interconnect Diagrams

Appendix A

Power Wiring Examples

You must supply input power components. The single-phase and three-phase line
filters are wired downstream of fusing and the M1 contactor.

In this example, the 2097-V31PR

x drives are wired to use the voltage doubling

circuit. The 120V input voltage provides 240V output to motors. The 2097-
V33PR

x drives are wired for single-phase 120V operation.

Figure 83 - Kinetix 300 Drive (120V single-phase input power)

PE

N

L1

+24V DC

+
+

SH

-
-

EN

ACOM

RDY +

RDY -

L1

L2/N

29
26

41

42

U
V

W

PE

L2/N

PE

L2

L3

L1

2097-V31PRx

2097-V33PRx

Return

Single-phase AC Input

120V rms AC, 50/60 Hz

Notes 1, 2

Bonded Cabinet
Ground Bus *

Ground Stud

Mains
Single-phase
AC Input
(IPD) Connector

Fuse Disconnect

or Circuit Breakers

Input Fusing *

M1 *

Notes 5, 7

Use discrete logic or PLC

to control ENABLE to drive

and monitor RDY signal

back from drive.

Shunt Resistor

and DC Bus

(BC) Connector

Motor Power

(MP) Connector

I/O (IOD)
Connector

Back-up Power
(BP) Connector

2097-V31PRx and 2097-V33PRx

Kinetix 300 Drives

* Indicates User Supplied Component

See table on

page 172

for note information.

AC Line Filter

(Optional)

Note 3

Three-phase
Motor Power
Connections

Note 9

Cable Shield
Clamp

Note 8

Shunt Resistor
Connections

User-supplied
+24V DC

Advertising