Single-phase power wired to single-phase drives, Voltage doubler operation – Rockwell Automation 2097-Vxxx Kinetix 300 EtherNet/IP Indexing Servo Drive User Manual User Manual

Page 60

Advertising
background image

60

Rockwell Automation Publication 2097-UM001D-EN-P - November 2012

Chapter 4

Connecting the Kinetix 300 Drive System

Single-phase Power Wired to Single-phase Drives

These examples illustrate grounded single-phase power wired to single-phase
Kinetix 300 drives when phase-to-phase voltage is within drive specifications.

Figure 35 - Single-phase Grounded Power Configurations

(1) This configuration applies to voltage-doubler operation for 2097-V31PRx drives.

Reducing transformer output reduces motor speed. Feeder and branch short
circuit protection is not illustrated.

Voltage Doubler Operation

You can wire the 2097-V31PR

x drives with 120V input power and achieve twice

the output voltage at half the output current, while maintaining the same output
power. To use the voltage-doubler circuit, connect the 120V single-phase input
power to the IPD-L1 and IPD-N terminals.

For Kinetix 300 drive power specifications, see Kinetix Servo Drives
Specifications Technical Data, publication

GMC-TD003

. For Kinetix 300 drive

input wiring diagrams, see

Power Wiring Examples on page 173

.

IMPORTANT

The 2097-V32PRx models have integrated AC line filters and do not require the
AC line filter shown in this diagram.

L1

L2

L1

L2 (Neutral)

IPD

L1

L2/N

L1

L2/N

L1

N

E

IPD

L1

L2

L1

L2

L1

L2/N

E

IPD

L1

L2

IPD

L1

L2

2097-V33PRx

2097-V31PRx

2097-V32PRx

Transformer Secondary

Transformer Secondary

Bonded Cabinet Ground Bus

Ground Grid or

Power Distribution Ground

AC Line

Filter

AC Line

Filter

120V AC

Output

240V AC

Output

Bonded Cabinet Ground Bus

Ground Grid or

Power Distribution Ground

Kinetix 300 Drives
Single-phase AC Input

Kinetix 300 Drives
Single-phase AC Input

M1

Contactor

Input Fusing

M1

Contactor

Input Fusing

2097-V31PRx

(1)

Advertising